Man-safe valves allow you to isolate positively a portion of your plant and then

To be man-safe, a valve needs to comply with these three conditions:

  1. they do not depend on any external medium to keep the closure element sealed and
  2. a seal leakage will not cause any harm to the operators and
  3. the closure element is designed to withstand the full operating condition on one side only.

For the first condition, the actuation uses a physical force (counterweight, spring) and does not rely on any external energy source. Alternatively, the closure element is installed in a way that the medium can not dislodge it.

To comply with the second condition, two sealing elements are installed in series with a vented cavity between them. The leaked medium doesn’t arm the operators, as long as the venting is completed safely and properly. This even if one seal is leaking. Both seals may be inside one valve or in two different valves. The first solution is more compact and economical but may introduce complexity during the isolation installation to test properly each seal independently. Furthermore, both seals need to be independent, for instance, one same cause may not introduce leak on both seals simultaneously.

The last condition required to properly consider the condition with the full operating condition on one valve side and atmospheric condition on the other side. Furthermore, the closure elements are also pressured retaining part similar to the main nozzle and need to comply with the relevant Pressure Equipment Regulation.

Of course, the extent to which these conditions are satisfied may differ according to the application and the risk/hazard associated with the specific pipeline isolation.